2023 New Handheld 2.8" Display Tiny Spectrum Analyzer TinySA ULTRA 4" Display 100kHz to 5.3GHz with 32GB Card Version V0.4.5.1
Regular price
Sale price
$50.47
/
SPECIFICATIONS
Brand Name: SeeSii
Hign-concerned Chemical: None
DIY Supplies: ELECTRICAL
Origin: Mainland China
Interface: USB
Display Size: 3.0 - 4.9 Inches
Average Noise Level: -89dBm & Under
Model Number: TinySA ULTRA
Feature 1: Spectrum Analyzer
Feature 2: TinySA ULTRA
Feature 3: 4" Display Apectrum Analyzer
Feature 4: Tiny Spectrum Analyzer
Feature 5: rf Spectrum Analyzer
Feature 6: Network Analyzer
There are 2 options, TinySA and TinySA Ultra, pls see below detials for differents, if you have any doubts, you can contact our service
TinySA model comparison table:
tinySA
tinySA Ultra
Display size
2.8 inch
4 inch
Max low input frequency
350MHz
800MHz, 6GHz in Ultra mode
High input range
240MHz - 960MHz
Not available
Resolution filters in 1,3,10 steps
from 3kHz to 600kHz
from 200Hz to 850kHz
Max low output frequency
350MHz
Sine wave up to 800MHz, Square wave up to 4.4GHz
Low output level
-76dBm to -7dBm
-104dBm to -16dBm
High output frequency range
240MHz - 960MHz
Not available
High output level
-32dBm to 16dBm
Not available
Ultra mode
Not available
Level calibrated up to 6GHz
Internal LNA gain
Not available
20dB up to 4GHz
Internal step attenuator
Normal: 0-31dB, High: NA
0-31dN
Displayed points per scan
max 290
max 450
0-350MHz scan time
405ms
165ms
Shortest zero span time
1.8ms
17ms
DANL low input at 100MHz
-146dBm/Hz
-153dBm/Hz (LNA Off) / -169dBm/Hz (LNA On)
DANL high input at 880MHz
-163dBm/Hz
Not available
DANL degrading in ultra mode
10dB above 2.5GHz, 25dB above 5.3GHz
Phase noise at 10kHz offset
-83dBc/Hz
-92dBc/Hz
Phase noise at 100kHz offset
-98dBc/Hz
-108dBc/Hz
Low input 1dB compression level
-0.5dBm
+0.5dBm (LNA Off) / -26.5dBm (LNA On)
IIP3 without LNA
+24dBm
+18dBm (at least 2MHz apart) / 0dBm (500Hz apart)
IIP3 with LNA
Not available
-8dBm (at least 2MHz apart)
SD card slot
Not available
micro SD card
Audio out
Not available
3.5mm headphone plug
FW update mode activation
Via DFU menu
Push jog button before switch on
AM modulation depth
Fixed 30%
10% and 100%
FM deviation
4kHz or 75kHz
1kHz to 300kHz
Modulation frequency
50Hz to 5kHz
50Hz to 5kHz(AM) or 1kHz(FM)
TinySA Option:
User interface: * Display resolution 320*240 pixels * Screen diagonal 2.8" * 16 bits per RGB pixels * Resistive touch control * Jog switch control * USB serial port control * Optional TTL USART port (SW not yet implemented) on the internal PCB * Linear power supply to avoid switching noise. *Add port ESD protection to upgrade version(V0.3.1_E)
The input/output specification of the tinySA is split over the 4 modes
Low input mode spec: * Input frequency range from 100kHz to 350MHz * Input impedance 50 ohm when input attenuation set to 10dB or more. * Selectable manual and automatic input attenuation between 0dB and 31dB in 1 dB steps * Absolute maximum input level without attenuation of +10dBm * Absolute maximum input power with 30dB attenuation of +20dBm for short period * Input Intercept Point of third order modulation products (IIP3) with 0dB attenuation of +15dBm * 1dB compression point at +2dBm with 0dB attenuation * Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB * Absolute power level accuracy after power level calibration of +/- 1dB * Lowest discernible signal using a resolution bandwidth of 30kHz of -102dBm * Frequency accuracy equal to the selected resolution bandwidth * Phase noise of -90dB/Hz at 100kHz offset and -115dB/Hz at 1MHz offset * Spur free dynamic range when using a 30kHz resolution bandwidth of 70dB * Manually selectable resolution filters of 3, 10, 30, 100, 300, 600kHz. Automatic selection of one of the 57 resolution filters. * On screen resolution of 145 or 290 measurement points. * Scanning speed of over 1000 points/second using largest resolution filters. * Automatic optimization of actual scanning points to ensure coverage of the whole scan range regardless of the chosen resolution bandwidth * Spur suppression option for assessing if certain signals are internally generated or actually present in the input signal
High input mode spec: * Input frequency range from 240MHz to 960MHz * As there is no input bandfilter strong signals outside the 240MHz to 960MHz range can cause distortion of the in band signals * Absolute maximum input level without attenuation of +10dBm * Input Intercept Point of third order modulation products (IIP3) of -5dBm * 1dB compression point at -6dBm with 0dB attenuation * Power detector resolution of 0.5dB and linearity versus frequency of +/-1dB * Absolute power level accuracy after power level calibration of +/- 1dB * Lowest discernible signal using a resolution bandwidth of 30kHz of -115dBm * Frequency accuracy equal to the selected resolution bandwidth * Spur free dynamic range when using a 30kHz resolution bandwidth of 50dB * Selectable (automatic and manual) resolution filters of 3, 10, 30, 100, 300 and 600kHz * Optional 25dB to 40dB frequency dependent input attenuator. The power level error with this attenuator activated increases to +/- 15dB * On screen resolution of 145 or 290 measurement points. * Scanning speed of over 1000 points/second using largest resolution filters. * Automatic optimization of actual scanning points to ensure coverage of the whole scan range regardless of the chosen resolution bandwidth
Low output mode spec: * Sinus output with harmonics below -40dB of fundamental * Output frequency range from 100kHz to 350MHz * Output level selectable in 1dB steps between -76dBm and -6dBm * Optional AM, narrow FM and wide FM modulation or slow sweep over selectable frequency span
High output mode spec: * Square wave output * Output frequency range from 240MHz to 960MHz * Output level selectable in variable increments between -38dBm and +13dBm * Optional narrow FM and wide FM modulation or slow sweep over selectable frequency span
Reference generator spec: * Optional square wave output with fundamental at -25dBm connected to high input/output * Frequency can be set to 1MHz, 2MHz, 4MHz, 10MHz, 15MHz or 30MHz.
Battery spec: * Charging time max 1 hour on 500mA minimum USB port or USB charger * Operation on fully charged battery for at least 2 hours
Package inclued: TinySA 2.8" Spectrum analyzer *1 20cm sma-sma rg174 rf cabe *2 USB Type-C Data Cable *1 Hand rope *1 SMA female to female connector *1 SMA telescopic antenna *1
TinySA ULTRA Option:
2023 New Handheld Tiny Spectrum Analyzer TinySA ULTRA 4" Display 100kHz to 5.3GHz with 32GB Card Version V0.4.5.1
Specification:
Parameter
Specification
Display size
4” TFT LCD (480×320)
Max low input frequency
800MHz, 6GHz in Ultra mode
Resolution filters in 1,3,10 steps
from 200Hz to 850kHz
Max output frequency
Sinus up to 800MHz, Square wave up to 4.4GHz
output level
-104dBm to -16dBm
Ultra mode
Level calibrated up to 5.3GHz
Internal LNA gain
20dB up to 4GHz
Displayed points per scan
max 450
0-350MHz scan time
165ms
Shortest zero span time
17ms
DANL at 100MHz
-153dBm/Hz (LNA Off) / -169dBm/Hz (LNA On)
DANL degrading in ultra mode
10dB above 2.5GHz, 25dB above 5.3GHz
Phase noise at 10kHz offset
-92dBc/Hz
Phase noise at 100kHz offset
-110dBc/Hz
Input 1dB compression level
+0.5dBm (LNA Off) / -26.5dBm (LNA On)
IIP3 without LNA
+18dBm (at least 2MHz apart) / 0dBm (500Hz apart)
IIP3 with LNA
-8dBm (at least 2MHz apart)
Frequency stability
<1ppm ( -10℃ ~ +55℃)
SD card slot
micro SD card
Audio out
3.5mm headphone plug
FW update mode activation
Push jog button before switch on
Maximum current consumption
330mA
Maximum charging current
1300mA
Battery
Li-polymer 3.7V 3000mAh
RF connectors
SMA female
Communication Interface
USB-CDC(Type-C),UART-TTL(2.54mm Connector)
Appearance Size
117x72x23mm (Excluding protruding parts)
Package includes: Host (with 3000mAh battery, 4"display) x 1 USB Type-C data cable x1 30cm ALSR100 SMA cables x2 SMA-SMA barrel connector x1 Antenna with SMA connector x1 Lanyard and touch plectrum x1 32GB MicroSD card(plugged in the host) x1